Nestec, Inc.
  • About
  • Solutions
    • Solutions
    • Thermal Oxidation Solutions
      • Thermal Oxidation Solutions
      • Regenerative Thermal Oxidizers
      • Catalytic Thermal Oxidizers
      • Recuperative Thermal Oxidizers
      • Direct-Fired Thermal Oxidizers
    • Auxiliary Clean Air Solutions
      • Auxiliary Clean Air Solutions
      • Capture Systems & Total Enclosures
      • Concentrator Systems
      • Particulate Control Systems
      • Scrubber Systems
    • Aftermarket Solutions
      • Aftermarket Solutions
      • Equipment Inspections
      • Rebuilds, Upgrades, & Repairs
      • Utility Reviews & Optimization
      • Replacement Parts
    • Mass Transfer Solutions
  • Case Studies
  • Resources
  • Industries
  • News
  • Contact Us
    • Contact Us
    • Careers
    • Locations
Case Studies
Wood Pellet Manufacturing Plant

Wood Pellet Manufacturing Plant

Georgia Biomass Wood Pellet Manufacturing
Location
Waycross, GA
Industry
Wood Pellet Manufacturing
Scope of Supply

100,000-SCFM and 150,000-SCFM RCOs installed on existing hammer mill (ten lines) and pellet mill cooler (five lines) baghouse exhaust ducts. Project included fabrication and installation of the RCOs, as well as design, fabrication and installation of two extensive and intricate exhaust duct systems connecting the customer mills to the RCOs. Included: five replacement exhaust fans, two emergency dump stacks, two 85-foot exhaust stacks, platforming, duct supports, exterior lighting, fire suppression systems, thermal insulation, control dampers, and return-to-process ducts.

 

At this existing wood pelletizing plant, organic emissions needed to be conveyed to two multi-chamber RCOs. Specifications included replacement of five process exhaust fans, as well as the supply of a complete exhaust duct system.

NESTEC contractors installed much of the duct, duct supports, and controls during normal plant operations, without disturbing production. Cut-ins to existing process stacks were made on carefully planned line shutdowns. The existing equipment layout inside the plant buildings was extremely tight, and the new duct had to be exactly placed. All specifications were accurately measured by NESTEC designers working in the field, and the resulting ductwork fit without problems.

“Exceptional care was taken to meet the stringent plant construction safety requirements.”

The tight six-month installation schedule was closely managed, and the October 2013 end date for Field Acceptance Tests was met. Exceptional care was taken to meet the stringent plant construction safety requirements.

The final system achieved the required destruction/reduction performance required by contract and state permits. The customer’s European-based project management team, which worked closely with NESTEC’s engineers and project manager, followed ISO 9001 procedures in managing the project. NESTEC performed on time and within budget.

  • Click to email this to a friend (Opens in new window)
  • Click to share on Facebook (Opens in new window)
  • Click to share on LinkedIn (Opens in new window)
  • Click to share on Twitter (Opens in new window)
  • Click to share on Pinterest (Opens in new window)
  • Click to share on Pocket (Opens in new window)
Previous Next
  • This field is for validation purposes and should be left unchanged.

Contact Us

Address
222 E. Main St.
PO Box 125
Pen Argyl, PA 18072
Phone
610-323-7670
Email
sales@nestecinc.com

We're Hiring!

Check out our Careers page.
Apply Now

Latest News

January 19, 2021
DRY Versus WET Air Emission Control System
READ MORE

December 17, 2020
Inefficient, Unreliable Air Emission Control Systems May Be Costing More Than You Think
READ MORE

Follow Us

  • Facebook
  • Twitter
  • LinkedIn

Join Our Newsletter

  • This field is for validation purposes and should be left unchanged.

Memberships

VERIFIED Seal EWTA Member
View Nestec, Inc. profile on Ariba Discovery
© 2021 | NestecInc.com | All Rights Reserved
loading Cancel
Post was not sent - check your email addresses!
Email check failed, please try again
Sorry, your blog cannot share posts by email.